Jul 27, 2012 , by
Public Summary Month 7/2012
As this is the last report of the EXECELL experiment we present the successful completion of the project. In this reporting period we finished Task 8 and Task 9, thus finally reaching the last milestone M3.
In Task 8 we analyzed the system behavior and identified the limitations of the detection capabilities of the sensor system by using various test criteria elaborated on basis of the Technical Report IEC 61496-4. So, the evaluation of the system represents first insights regarding a future safety certification and its feasibility. Beside the analysis of the response time, especially the examination of object properties and their influences to the detection capabilities were involved.
Task 9 handles the implementation and execution of the use cases defined in Task 2. Here, the focus was on using both safety space calculation approaches, the global one and the dynamic one.